CJX2-D(XLC1 -D) Series AC Contactor

Short Description:

Application

CJX2-D series AC contactor is suitable for using in the circuits up to the rated voltage 660V AC 50/60Hz, rated current up to 660V, for making, breaking, frequently starting & controlling the AC motor, combined with the auxiliary contact block, timer delay & machine-interlocking device etc., it becomes the delay contactor mechanical interlocking contactor, star-delta starter, with the thermal relay, it is combined into the electromagnetic starter.


Product Detail

Product Tags

Specifications

Type D09 D12 D18 D25 D32 D40 D50 D65
Rated working current(A) AC3 9 12 18 25 32 40 50 65
AC1 3.5 5 7.7 8.5 12 18.5 24 28
AC-3 level

AC3 capacity of phase 3squirrel-cage motor AC3(KW)

220/230V 2.2 3 4 5.5 7.5 11 15 18.5
380/400V 4 5.5 7.5 11 15 18.5 22 30
415V 4 5.5 9 11 15 22 25 37
500V 5.5 7.5 10 15 18.5 22 30 37
5.5 7.5 10 15 18.5 30 33 37
Rated heat current(A) 660/690V 20 20 32 40 50 60 80 80
Electrical life AC3X10, 100 100 100 100 80 80 60 60
AC4X101 20 20 20 20 20 15 15 15
Meeh anical lifeXW 100 1000 1000 1000 800 800 800 800
Number of the contacts 3P+NO 3P+NO+NC

Dimension & Mounting Size

for CJX2-D09-95 contactors

product-description1

product-description2

Standard Control Circuit Voltages

Volts 24 42 48 110 220 230 240 380 400 415 440 500 660
50Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5
60Hz B6 D6 E6 F6 M6 P6 U6 Q6 V6 N6 R6 S6 Y6
50/60HZ B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7

Specifications

D80 D95 D115 D150 D170 D205 D245 D300 D410 D475 D620
80

95

115 150 170 205 245 300 410 475 620
37 44 52 60 75 85 105 117 138 147 180
22

25

30 40 55 63 75 100 110 147 200
37

45

55 75 90 110 132 160 220 265 335
45

45

59 80 100 110 132 180 220 280 375
55

55

75 90 110 129 160 200 250 355 400
45

55

80 100 110 129 160 220 280 355 450
125 125 200 250 250 275 315 400 500 700 1000
60 60 200 60 60 50 50 50 30 30 20
10 10 15 15 15 15 15 15 8 8 5
600 600 300 300 300 300 300 300 100 100 100
3P+NC+NO

product-description3

Specifications

Type CJX2-D115 CJX2-D150
Rated current AC3 Ue< 440V A 115 150
Rated heating current Ac 10 w40°C A 200 250
Rated power Ac3 Three-phase motor OwAuxiliary contactor block (Recommend to use) 220/240V KW 30 40
380/400V KW 55 75
400V KW 59 80
500V KW 75 90
600/690V KW 80 100
1000V KW 75 90
Rated power Ac4

Three-phase motor

0<40

200/230V KW 9 11
380V/400V KW 18.5 22
440V KW 18.5 22
500V KW 30 37
Weight Kg 2.25 2.25
VolumeLxWxH mm3 132x 120x 158 132x 120x 158
Section of power connecting wire mm2 120 120
Installment Bott HXL-ø

Guiding rail Number of guiding rail Xwidth of rail X Rail center distance

mm 130x(95-110)-6.5

2 x 35 x 100

130x(95-110)-6.5

2 x 35 x 100

Reference model LC1-D115 LC1-D150
Control Circuit Voltage AC 50HZ V 24(B5) 42(D5) 48(E5)
AC 60HZ V 24(B6) 42(D6) 48(E6)
AC 50/60HZ V 24(B7) 42(D7) 48(E7)
DC V 24(BD) 48(ED) 60(ND)
Auxiliary contactor block (Recommend to use) Auxiliary instantaneous contactor block, contactor 1

LA1-DN10C

LA1-DN01C

 

Auxiliary instantaneous

contactor block. Contactor H

LA1-DN11C

LA1-DN20C

LA1-DN02C

Reversible contactor    Thermal overload     Surge inhibiting module

 

Add 2 instantaneous contact sets extra   

Not increase the height of cabinet、Other modules can be added on the frontal of controlling relay

Applicable for the contactor and controlling relay below D170.

.

LR2-D43.C(Recommend to use)